ONTAP 9 Administration and MetroCluster Installation (CDOTMC) – Outline

Detailed Course Outline

From the ONTAP 9 Administration course:

  • Module 1: Introducing ONTAP 9
  • Module 2: The Cluster: Concepts and Initial Set Up
  • Module 3: The Cluster: Management
  • Module 4: ONTAP Storage Architecture
  • Module 5: Networking
  • Module 6: Data Protocols
  • Module 7: Maintenance
  • Module 8: Data Protection

From the MetroCluster Installation course:

Module 1: MetroCluster Overview

  • MetroCluster Introduction
  • Define MetroCluster
  • Describe MetroCluster Architecture
  • Configuration Replication Service (CRS)
  • Limitations
  • MetroCluster supported configuration
  • Controllers
  • Shelves
  • Switches and ISL configuration
  • FAS8020, FAS8040, FAS8060 and FAS8080EX
  • FlexArray virtualization support
  • MetroCluster implementation overview
  • Setup
  • MetroCluster configuration tools and documentation
  • Hardware
  • Materials
  • Technical content

Module 2: MetroCluster Cabling

  • Disk requirements
  • Plex SyncMirror overview
  • Shelf IDs
  • Cabinet Layout
  • LUN layout with FlexArray storage virtualization software
  • ATTO FibreBridge
  • Cabling Shelves to Bridges
  • Cabling Bridges to FC switches
  • Controller Cabling
  • Cluster Interconnect
  • FC-VI Interconnect
  • Onboard ports or HBAs
  • CRS
  • Management and data LIFs
  • FC switch cabling
  • Switch alternatives
  • Brocade 6505 and 6510
  • Cisco 9148

Module 3: Bridge and Switch Configuration

  • ATTO FibreBridge configuration
  • Brocade FC switch configuration
  • FC switches
  • Configuration
  • RCF domains
  • RCF ports and zone settings
  • Brocade ISL configuration
  • Calculating and setting distance
  • Verifying
  • OOD configuration – ONTAP 9 and later

Module 4: Cluster Configuration

  • Controller configuration
  • Setup
  • Disk ownership
  • FlexArray storage virtualization software
  • Cluster setup

Module 5: MetroCluster Configuration

  • MetroCluster setup
  • Prerequisites
  • Peer relationship
  • Mirror aggregates
  • Create mirrored data aggregates
  • Enable configuration replication
  • MetroCluster configure command
  • MetroCluster verification
  • Disk ownership fields
  • Monitor FC switches
  • Monitor FibreBridge devices
  • Cluster status
  • MetroCluster plug-in
  • CLI health monitoring
  • Node verification
  • Components
  • CRS component
  • Interconnect mirror
  • OnCommand unified manager
  • Connectivity monitoring
  • Replication monitoring
  • Events and alerts
  • SVM configuration in a MetroCluster environment
  • Setup
  • CLI
  • Automatic creation

Module 6: Failure Scenarios

  • Failures:
  • Bridge
  • Switch or switch port
  • Single path
  • Shelf
  • CRS
  • ISL
  • Single HA node
  • Double HA node
  • Data center site
  • Switchover types
  • Simulation
  • Negotiated switchover
  • Non-negotiated switchover
  • Switchover operation
  • Switchback
  • Switchback process

Module 7:Tiebreaker Configuration

  • Tiebreaker software
  • Disaster Detection
  • Normal operation
  • Tiebreaker installation
  • Service operations
  • Configuration
  • Commands
  • Monitor creation
  • AutoSupport
  • SNMP
  • Appendix A: Advanced Administration
  • Appendix B: Basic Metrocluster Troubleshooting
  • Appendix C: Front-End FC Fabrics in MetroCluster